Product Image
Product added to your wishlist! View wishlist
Sign in to see your saved products on any device
Product removed from your wishlist! View wishlist
Sign in to see your saved products on any device
Something went wrong. Please try again later.
Product is added to compare already. Please refresh the page.
Product is not found in compare. Please refresh the page.
5 Products already added. Please delete existing selection to add this.

Share this product

IOTA IQ-4 Smart Controller for 3 stage charging with DLS Chargers
This product ad may change over time
Share ProductShare

IOTA IQ-4 Smart Controller for 3 stage charging with DLS Chargers

IOTA IQ-4 Smart Controller The IQ-4 makes the DLS charger into 3-stage charge with bulk, absorption and float charging. If the battery remains in float stage for 7 days, it delivers a bulk charge. The IQ Smart Controller is compatible with any DLS Battery Charger model and is covered under our standard Two-Year Warranty. The standard IQ4 …
IOTA IQ-4 Smart Controller The IQ-4 makes the DLS charger into 3-stage charge with bulk, absorption and float charging. If the battery remains in float stage for 7 days, it delivers a bulk charge. The IQ Smart Controller is compatible with any DLS Battery Charger model and is covered under our standard Two-Year Warranty. The standard IQ4 is for all chargers that will be used as a single unit. The IQ4/PAR is a special one for using TWO DLS chargers in parallel on a single battery bank to keep them charging evenly. Reduced Charge Times The Bulk Stage allows the batteries to be charged from the full rated load of the charger. During this stage the batteries are recharged quickly to reduce charge times Increased Battery Capacity After the Bulk Stage, the batteries are held in the Absorption Stage for a controlled period, insuring a full and complete charge. Reduced Battery Stress During the Float Stage, the DLS charge voltage is reduced. This minimizes gassing while maintaining a full charge at the nominal rate of the battery. Weekly Equalization for Longer Battery Life If the batteries have not received a "smart charge" during a seven-day period, the IQ Controller will switch the DLS charger into a pre-programmed equalization stage to top off the batteries, dissolving any sulfate layer on the battery's internal plates and avoiding stratification. LED Indicator The LED Indicator on the IQ4 informs the user as to the status of the battery and the charging stage. When first activated, the IQ4 will read the number of cells in the battery and indicate the voltage of the battery through a number of flashes. 6 flashes = 12 volt battery 12 flashes = 24 volt battery 18 flashes = 36 volt battery 24 flashes = 48 volt battery After reading the battery, the IQ4 will initiate either a Bulk Charge phase or Float Charge phase depending on the battery's charge status. When the IQ4 is in the Bulk Charge mode, the green LED indicator will flash rapidly. When the Bulk Charge is complete, the IQ4 begins the Absorption Charge and the LED indicator will flash at a slower rate. When the battery charging is complete and the IQ4 begins the Float Charge, the LED will remain lit and no longer flash. If, when first activated, the battery is not in need of charging, the IQ4 will immediately begin the Float charge phase and the LED will be remain lit after it has counted the battery cells. Charging Voltages The charging voltages used to charge the battery during the three stages differ depending on the voltage of the battery being charged. If you are interested in knowing the various voltages, they are easy to calculate. Follow the simple steps below: 1) Determine the number of cells your battery has by counting the flashes on the IQ4 when it is first activated (1 flash = 1 cell) 2) Multiply the number of cells by the appropriate voltage for the individual charging stage. Use the table below for reference: Charging Phase Voltage Charge per Cell Bulk Charge 2.46 Absorption Charge 2.36 Float Charge 2.26 Example: A 12V battery (6 cells) will Bulk Charge at 14.76V (6 x 2.46). Technical Note: For smart-charge control of the DLS-54.4-15, use the IQ4-54V model.
See more below
T
The Solar Store
$49.61
Visit site

Description

IOTA IQ-4 Smart Controller The IQ-4 makes the DLS charger into 3-stage charge with bulk, absorption and float charging. If the battery remains in float stage for 7 days, it delivers a bulk charge. The IQ Smart Controller is compatible with any DLS Battery Charger model and is covered under our standard Two-Year Warranty. The standard IQ4 is for all chargers that will be used as a single unit. The IQ4/PAR is a special one for using TWO DLS chargers in parallel on a single battery bank to keep them charging evenly. Reduced Charge Times The Bulk Stage allows the batteries to be charged from the full rated load of the charger. During this stage the batteries are recharged quickly to reduce charge times Increased Battery Capacity After the Bulk Stage, the batteries are held in the Absorption Stage for a controlled period, insuring a full and complete charge. Reduced Battery Stress During the Float Stage, the DLS charge voltage is reduced. This minimizes gassing while maintaining a full charge at the nominal rate of the battery. Weekly Equalization for Longer Battery Life If the batteries have not received a "smart charge" during a seven-day period, the IQ Controller will switch the DLS charger into a pre-programmed equalization stage to top off the batteries, dissolving any sulfate layer on the battery's internal plates and avoiding stratification. LED Indicator The LED Indicator on the IQ4 informs the user as to the status of the battery and the charging stage. When first activated, the IQ4 will read the number of cells in the battery and indicate the voltage of the battery through a number of flashes. 6 flashes = 12 volt battery 12 flashes = 24 volt battery 18 flashes = 36 volt battery 24 flashes = 48 volt battery After reading the battery, the IQ4 will initiate either a Bulk Charge phase or Float Charge phase depending on the battery's charge status. When the IQ4 is in the Bulk Charge mode, the green LED indicator will flash rapidly. When the Bulk Charge is complete, the IQ4 begins the Absorption Charge and the LED indicator will flash at a slower rate. When the battery charging is complete and the IQ4 begins the Float Charge, the LED will remain lit and no longer flash. If, when first activated, the battery is not in need of charging, the IQ4 will immediately begin the Float charge phase and the LED will be remain lit after it has counted the battery cells. Charging Voltages The charging voltages used to charge the battery during the three stages differ depending on the voltage of the battery being charged. If you are interested in knowing the various voltages, they are easy to calculate. Follow the simple steps below: 1) Determine the number of cells your battery has by counting the flashes on the IQ4 when it is first activated (1 flash = 1 cell) 2) Multiply the number of cells by the appropriate voltage for the individual charging stage. Use the table below for reference: Charging Phase Voltage Charge per Cell Bulk Charge 2.46 Absorption Charge 2.36 Float Charge 2.26 Example: A 12V battery (6 cells) will Bulk Charge at 14.76V (6 x 2.46). Technical Note: For smart-charge control of the DLS-54.4-15, use the IQ4-54V model.

Specifications

BrandIota
ManufacturerIota
ModelIq-4